โš™ CalibKeepr Plant 1 ยท ISO 9001 / IATF 16949
๐Ÿ“ Calibration Specs (SOPs)

CalibKeepr ยท Metrology Schedule

Tool Calibration Schedule & Execution

Track overdue, cycle-triggered, and upcoming calibrations. Click any tool to see what the calibration needs to be and log step-by-step As-Found / As-Left readings.

Overdue & Quarantined 3
Cycle-Triggered / Due Soon 3
Total Active Tools 8
Calibrated & In Spec 2

Filters & Sort

Scheduled Tool Calibrations

Select any tool to inspect its required SOP steps, reference standard, ambient temp/humidity range, and measurement tolerances, or to record a calibration.

8 tool(s)
🛑 Quarantined / Out of Tolerance (Do Not Use) 1 tool(s)
TMP-505 Heat Treat & Hydraulic Test Bay Quarantined (OOT)

Omega Platinum RTD Curing Oven Probe #1 (50–250 °C)

Failed 250.0 °C checkpoint (+1.65 °C drift vs ±1.00 °C limit). Tagged RED Out-of-Tolerance pending replacement.

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-510 โ€” Curing Oven RTD & Infrared Pyrometer Dry-Block Calibration (50–250 °C) (AMS 2750G Pyrometry)
๐Ÿ› Reference Standard: STD-TMP-04 (Fluke 1524 Reference Thermometer with Secondary PRT Probe ยท NIST-831/509311-26) ๐ŸŒก Environment: 19โ€“23 ยฐC, 30โ€“55% RH (45 min soak)
Low Setpoint (50 °C): 50 ยฑ0.5 °C (49.5โ€“50.5)Cure Soak Setpoint (150 °C): 150 ยฑ0.8 °C (149.2โ€“150.8)High Limit Setpoint (250 °C): 250 ยฑ1 °C (249โ€“251)
Next Calendar Due Dec 26, 2026
Usage Cycles 0 / 1,000 (0%)
🚨 Overdue Calibrations (Past Calendar Due Date) 2 tool(s)
TRQ-204 Final Assembly Line 2 Overdue (5d)

Snap-on TechAngle Electronic Torque Wrench (10–100 Nm)

Calendar calibration interval (60d) expired on Oct 4, 2026.

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-204 โ€” Electronic & Click Torque Wrench Verification (20%, 60%, 100% Scale) (ISO 6789-1:2017)
๐Ÿ› Reference Standard: STD-TRQ-02 (CDI Suretest 5000-ST Master Torque Transducer Bench ยท NIST-822/771204-25) ๐ŸŒก Environment: 18โ€“24 ยฐC, 30โ€“60% RH (30 min soak)
Low Range (20% Scale): 20 ยฑ0.8 Nm (19.2โ€“20.8)Mid Range (60% Scale): 60 ยฑ2.4 Nm (57.6โ€“62.4)Full Scale (100% Scale): 100 ยฑ4 Nm (96โ€“104)
Next Calendar Due Oct 4, 2026
Usage Cycles 1,720 / 2,500 (69%)
PRG-302 Heat Treat & Hydraulic Test Bay Overdue (3d)

Ashcroft Digital Test Pressure Gauge (0–500 PSI)

Calendar calibration interval (120d) expired on Oct 6, 2026.

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-405 โ€” Hydraulic Digital Pressure Gauge 4-Point Rising/Falling Calibration (0–500 PSI) (ASME B40.100)
๐Ÿ› Reference Standard: STD-PRS-03 (Fluke 754 Documenting Process Calibrator + 750P06 Module ยท NIST-836/610942-26) ๐ŸŒก Environment: 18โ€“25 ยฐC, 25โ€“65% RH (30 min soak)
Ambient Vented Zero (0% FS): 0 ยฑ0.5 PSI (-0.5โ€“0.5)Quarter Span (25% FS): 125 ยฑ1.5 PSI (123.5โ€“126.5)Mid Span (50% FS): 250 ยฑ1.5 PSI (248.5โ€“251.5)Full Scale Proof (100% FS): 500 ยฑ1.5 PSI (498.5โ€“501.5)
Next Calendar Due Oct 6, 2026
Usage Cycles 300 / 1,500 (20%)
🔄 Usage / Cycle-Count Triggered Calibrations 1 tool(s)
TRQ-209 Final Assembly Line 2 Cycle Limit (2,640/2,500)

Desoutter DC Electric Nutrunner Spindle #2 (10–100 Nm)

Usage limit reached (2,640 of 2,500 cycles since last calibration). Calibrate before next shift.

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-204 โ€” Electronic & Click Torque Wrench Verification (20%, 60%, 100% Scale) (ISO 6789-1:2017)
๐Ÿ› Reference Standard: STD-TRQ-02 (CDI Suretest 5000-ST Master Torque Transducer Bench ยท NIST-822/771204-25) ๐ŸŒก Environment: 18โ€“24 ยฐC, 30โ€“60% RH (30 min soak)
Low Range (20% Scale): 20 ยฑ0.8 Nm (19.2โ€“20.8)Mid Range (60% Scale): 60 ยฑ2.4 Nm (57.6โ€“62.4)Full Scale (100% Scale): 100 ยฑ4 Nm (96โ€“104)
Next Calendar Due Oct 31, 2026
Usage Cycles 2,640 / 2,500 (106%)
⏰ Due Soon (Within Reminder Window) 2 tool(s)
CAL-104 CNC Machining Cell A Due in 4d

Mitutoyo Absolute Digimatic Caliper 0–150 mm

Within 14-day reminder window (due Oct 13, 2026).

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-101 โ€” Digital & Dial Caliper 4-Point Dimensional Calibration (0–150 mm) (ISO 13385-1:2019)
๐Ÿ› Reference Standard: STD-GB-01 (Mitutoyo Grade 0 Master Gage Block Set (81-Piece) ยท NIST-821/294810-26) ๐ŸŒก Environment: 18โ€“22 ยฐC, 35โ€“55% RH (60 min soak)
Closed Outside Jaws (Zero): 0 ยฑ0.01 mm (-0.01โ€“0.01)Outside Jaw — 25 mm Gage Block: 25 ยฑ0.02 mm (24.98โ€“25.02)Outside Jaw — 75 mm Gage Block: 75 ยฑ0.02 mm (74.98โ€“75.02)Outside Jaw — 150 mm Gage Block: 150 ยฑ0.02 mm (149.98โ€“150.02)
Next Calendar Due Oct 13, 2026
Usage Cycles 3,920 / 5,000 (78%)
MIC-112 CNC Machining Cell A Due in 9d

Starrett Coolant-Proof Outside Micrometer 0–25 mm

Due Oct 18, 2026 AND at 87% of max cycle interval (2,620/3,000 cycles).

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-302 โ€” Outside Micrometer Optical Flat & Gage Block Calibration (0–25 mm) (ISO 3611:2023)
๐Ÿ› Reference Standard: STD-GB-01 (Mitutoyo Grade 0 Master Gage Block Set (81-Piece) ยท NIST-821/294810-26) ๐ŸŒก Environment: 19โ€“21 ยฐC, 35โ€“50% RH (120 min soak)
Anvil Contact Zero: 0 ยฑ0.001 mm (-0.001โ€“0.001)6.500 mm Fractional Rotation: 6.5 ยฑ0.002 mm (6.498โ€“6.502)12.500 mm Half-Span Block: 12.5 ยฑ0.002 mm (12.498โ€“12.502)25.000 mm Full-Span Block: 25 ยฑ0.002 mm (24.998โ€“25.002)
Next Calendar Due Oct 18, 2026
Usage Cycles 2,620 / 3,000 (87%)
✅ Calibrated & Upcoming Schedule 2 tool(s)
CAL-108 Quality Metrology Lab Calibrated

Mitutoyo Digimatic Height Gauge & Master Caliper

Next scheduled calibration on Dec 14, 2026 (66 days remaining).

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-101 โ€” Digital & Dial Caliper 4-Point Dimensional Calibration (0–150 mm) (ISO 13385-1:2019)
๐Ÿ› Reference Standard: STD-GB-01 (Mitutoyo Grade 0 Master Gage Block Set (81-Piece) ยท NIST-821/294810-26) ๐ŸŒก Environment: 18โ€“22 ยฐC, 35โ€“55% RH (60 min soak)
Closed Outside Jaws (Zero): 0 ยฑ0.01 mm (-0.01โ€“0.01)Outside Jaw — 25 mm Gage Block: 25 ยฑ0.02 mm (24.98โ€“25.02)Outside Jaw — 75 mm Gage Block: 75 ยฑ0.02 mm (74.98โ€“75.02)Outside Jaw — 150 mm Gage Block: 150 ยฑ0.02 mm (149.98โ€“150.02)
Next Calendar Due Dec 14, 2026
Usage Cycles 650 / 5,000 (13%)
MIC-118 Quality Metrology Lab Calibrated

Mitutoyo QuantuMike IP65 Digital Micrometer 0–25 mm

Next scheduled calibration on Mar 19, 2027 (161 days remaining).

๐Ÿ“ What the Calibration Needs to Be: SOP-CAL-302 โ€” Outside Micrometer Optical Flat & Gage Block Calibration (0–25 mm) (ISO 3611:2023)
๐Ÿ› Reference Standard: STD-GB-01 (Mitutoyo Grade 0 Master Gage Block Set (81-Piece) ยท NIST-821/294810-26) ๐ŸŒก Environment: 19โ€“21 ยฐC, 35โ€“50% RH (120 min soak)
Anvil Contact Zero: 0 ยฑ0.001 mm (-0.001โ€“0.001)6.500 mm Fractional Rotation: 6.5 ยฑ0.002 mm (6.498โ€“6.502)12.500 mm Half-Span Block: 12.5 ยฑ0.002 mm (12.498โ€“12.502)25.000 mm Full-Span Block: 25 ยฑ0.002 mm (24.998โ€“25.002)
Next Calendar Due Mar 19, 2027
Usage Cycles 170 / 3,000 (6%)
An unhandled error has occurred. Reload ๐Ÿ—™